Autoranging EC, TDS, NaCl, Temperature Bench Meter 230V
Sale!

Autoranging EC, TDS, NaCl, Temperature Bench Meter 230V

Original price was: $230.00.Current price is: $57.50.

SKU: 5690379 Category:

Description

Clarkson HI2300-02
Autoranging EC, TDS, NaCl, Temperature Bench Meter 230V
Hanna Instruments HI 2300-02

  •  Autoranging; The EC and TDS scales are autoranging. The meter automatically sets the scale with the highest possible resolution.
  • Manual range selection and range lock
  • Four ring potentiometric conductivity probe with internal temperature sensor
  • Automatic (ATC), manual (MTC) or no temperature compensation (NoTC)
  • GLP features
  • Log-on-demand up to 500 records
  • PC compatible via USB

HI 2300 measures EC, TDS, NaCl and temperature. In conductivity and TDS ranges (up to 500 mS/cm and 400 g/L respectively) the instrument
automatically chooses the best scale to maintain the highest accuracy.

EC calibration is a one-point procedure. Selectable calibration points are 0.00 µS, 84.0 µS, 1413 µS, 5.00 mS, 12.88 mS, 80.0 mS, and 111.8 mS
selected according with the expected measurement range. NaCl calibration is a one-point procedure at 100.0% NaCl. Use HI 7037L calibration
solution as a 100% NaCl standard solution. This instrument utilizes a four ring potentiometric probe with platinum sensors to offer versatility over
typical amperometric designs. By utilizing the four ring method, it is possible to measure very low or high conductivity levels without changing probes.
Three options of compensating for temperature are available for this instrument:       

Automatic (ATC): The EC probe has a built-in temperature sensor which is used to automatically compensate the EC/TDS reading (from -9.9°C to 120.0°C),
using the selected reference temperature (20 or 25ºC) and temperature compensation coefficient from (0.0 to 6.0%)/ºC

Manual (MTC): The temperature value, shown on the secondary LCD, can be manually set with the ARROW keys. The compensation is referenced at
the selected temperature. All the other parameters of temperature compensation are settable similar to ATC.

No Compensation (NoTC): For actual conductivity or TDS measurement, the temperature value shown on the secondary LCD is not taken into account.

Cell constant is selectable between 0.5 and 1.700. TDS factor is selectable between 0.40 and 0.80.

The HI 2300 also provides users with GLP capabilities. Good Laboratory Practice (GLP) is a set of functions that allows storage and retrieval of data
regarding the status of the system.

After a successful calibration, the meter automatically stores the date and time of calibration, the calibration solution used and the resulting cell constant value.
All this information can be later recalled by the user. Other features include a lock range function and stability indicator.

For PC communication, use the optional HI 92000 software and HI 920013 USB cable. The software is provided with an exclusive online guide of all
the commands available and allows data printing, plotting and exporting.

Specifications:

Range EC 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm;
30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC)
TDS 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt);
15.0 to 100.0 g/L (ppt); up to 400.0 g/L (actual TDS), with 0.80 conversion factor
NaCl 0.0 to 400.0%
Temperature -20.0 to 120.0°C
Resolution EC 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm
TDS 0.01 mg/L; 0.1 mg/L; 1 mg/L; 0.01 g/L; 0.1 g/L
NaCl 0.1%
Temperature 0.1°C
Accuracy @ 25°C EC ±1% of reading ± (0.05 µS/cm or 1 digit)
TDS ±1% of reading ± (0.03 mg/L or 1 digit)
NaCl ±1% of reading
Temperature ±0.4°C
Calibration EC automatic, one point with six memorized values (84, 1413, 5000, 12880, 80000, 111800 µS/cm)
NaCl one point, with HI 7037 calibration solution
Temperature two point, at 0 and 50°C
Temperature Compensation automatic or manual from -20.0 to 120.0°C
Temperature Coefficient selectable from 0.00 to 6.00%/°C (EC and TDS only)
TDS Factor selectable from 0.40 to 0.80 (default value: 0.50)
Probe HI 76310 platinum, four ring conductivity/TDS probe with internal temperature sensor and
1 m (3.3′) cable (included)
PC Connection opto-isolated USB
Logging log on demand, 500 samples
Auto-off after five minutes of non-use (can be disabled)
Power Supply 12 VDC adapter (included)
Environment 0 to 50°C (32 to 122°F); RH max 95%
Dimensions 235 x 218 x 108 mm (9.2 x 8.5 x 4.2”)
Weight 1.3 kg (2.9 lbs.)

Accessories:

Solutions
HI 7030L 12880 µS/cm EC Solution, 500 mL Bottle
HI 7031L 1413 µS/cm EC Solution, 500 mL Bottle
HI 7033L 84 µS/cm EC Solution, 500 mL Bottle
HI 7034L 80000 µS/cm EC Solution, 500 mL Bottle
HI 7035L 111800 µS/cm EC Solution, 500 mL Bottle
HI 7039L 5000 µS/cm EC Solution, 500 mL Bottle
HI 7037L Calibration Solution for % Readings (100% NaCl)
HI 7061L General Purpose Cleaning Solution 1 x 500 mL bottle
Accessories
HI 92000 Windows® Compatible Software
HI 920013 USB Cable
HI 76404N Electrode Holder for HI 42xx Type Bench Meters
Probes
HI 76310 4-Ring Platinum Potentiometric EC/TDS Probe for use with HI 3512, HI 2300 and HI 2550

Order Information:
HI 2300-01 (115V) and HI 2300-02 (230V) is supplied with HI 76310 conductivity probe, 12 VDC adapter and instructions.

Downloads:
Manual: (Download)

Reviews

There are no reviews yet.

Be the first to review “Autoranging EC, TDS, NaCl, Temperature Bench Meter 230V”