Calibration Check pH/ORP/Temperature Benchtop Meter 0.001 Resolution 230V
Sale!

Calibration Check pH/ORP/Temperature Benchtop Meter 0.001 Resolution 230V

Original price was: $230.00.Current price is: $57.50.

SKU: 437122 Category:

Description

Clarkson HI2223-02
Calibration Check pH/ORP/Temperature Benchtop Meter 0.001 Resolution 230V
Hanna Instruments HI 2223-02

  • pH Calibration Check™
  • On-screen electrode condition and response time
  • Up to five point calibration with seven standard buffers
  • Diagnostic alerts through icons
  • Automatic Temperature Compensation
  • Log up to 500 samples
  • GLP features
  • PC interface via US

A properly manufactured and maintained pH electrode will retain its measuring integrity for a long time. As a result of many factors such as age, poor maintenance or improper handling, any electrode in time will lose its integrity.

The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration.

A dirty electrode or wrong calibration approach can contribute to buffer solution contamination. A contaminated buffer solution can present a major problem during calibration due to the fact that it is considered the only reference.

The HI 2223 is a pH benchtop meter featuring our exclusive Calibration Check™ diagnostics for both pH?electrodes and buffer solutions during calibration. This instrument compares the characteristics of the pH electrode from one calibration to the next. In the case of large variances in the electrode condition, it alerts the user that the electrode needs to be properly cleaned prior to calibration and measuring.

The second feature is to detect if the calibration buffer solution is contaminated. After calibration, the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.

This meter can measure using ORP electrodes (pH channel input), due to it’s capability to measure mV with a resolution up to 0.1 mV.

HI 2223 also features five point calibration with seven standard buffers, Automatic Temperature Compensation and GLP capabilities that allow for the storage and retrieval of all data regarding pH. With a built-in logging function, measurements are stored in non volatile memory and can be transferred to a PC through the USB port. Users can manually log up to 200 records and interval log up to 500 records.

Specifications:

Range pH –2.00 to 16.00 pH; –2.000 to 16.000 pH
mV ±999.9 mV; ±2000 mV
Temperature – 20.0 to 120.0 °C
Resolution pH 0.01 pH; 0.001 pH
mV 0.1mV(± 999.9mV); 1mV(± 2000mV)
Temperature 0.1 °C
Accuracy pH ±0.01 pH; ±0.002 pH
mV ±0.2mV(± 999.9mV);
Temperature ± 0.2 °C (excluding probe error)
pH Calibration Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
Temperature Compensation Manual or automatic from -20 to 120°C
Temperature Probe HI 1131P glass body, single junction, refillable with BNC connection and 1 m (3.3′) Cable HI 7662 stainless steel probe
PC Connection USB
Data Logging 500 points
Dimensions 235 x 222 x 109 mm (9.2 x 8.7 x 4.3″)
Weight 1.3 kg (2.9 lb.)

Accessories:

Electrodes
HI 1131P Refillable, Combination pH Electrode for the Laboratory and Beer Testing BNC + pin Connection
Solutions
HI 70300L Electrode Storage Solution 1 x 500 mL bottle
HI 7004L 4.01 pH Buffer Solution 1 x 500 mL bottle
HI 7007L 7.01 pH Buffer Solution 1 x 500 mL bottle
HI 7010L 10.01 pH Buffer Solution 1 x 500 mL bottle
Accessories
HI 92000 Windows® Compatible Software
HI 76404N Electrode Holder for HI 42xx Type Bench Meters
Probes
HI 7662 Stainless Steel Temperature Probe
ORP Calibration Solutions
HI 7091L Reducing Pretreatment Solution 1 x 500 mL bottle
HI 7092L Oxidizing Pretreatment Solution 1 x 500 mL bottle

Order Information:
HI 2223-01 (115V) and HI 2223-02 (230V) are supplied with HI 1131B pH electrode, HI 7662 temperature probe,
HI 76404N electrode holder, HI 70004 pH 4.01 buffer solution sachet, HI 70007 pH 7.01 buffer solution sachet,
HI 700661 cleaning solution sachet, HI 7071S electrolyte solution (30 mL), 12 VDC adapter and instructions.

Downloads:
Manual: (Download)

Reviews

There are no reviews yet.

Be the first to review “Calibration Check pH/ORP/Temperature Benchtop Meter 0.001 Resolution 230V”

Your email address will not be published. Required fields are marked *